When an air handling unit drops airflow, trips a VFD, or floods a drain pan, occupied floors feel it within the hour. Com+ Mechanical diagnoses and repairs commercial AHUs, built-up units, and penthouse air handlers throughout the five boroughs, Nassau, Westchester, northern NJ, and Stamford. We get supply and return air back to design conditions and keep your tenants comfortable.
Often a broken or badly slipping fan belt, a seized fan bearing, a VFD that has faulted to zero speed, or a loaded filter bank driving static pressure beyond the fan curve. We isolate the mechanical versus drive versus filter cause and restore design CFM.
Worn fan or motor bearings, a misaligned or loose sheave, an unbalanced fan wheel, or a frayed belt. Left alone these escalate to a thrown belt or a catastrophic bearing failure that takes the whole unit offline.
A stratified mixed-air temperature, a stuck outside-air damper letting in subfreezing air, or a failing freeze-stat capillary. On hydronic coils this is a real freeze-burst risk, so we correct the root cause, not just reset the alarm.
A clogged condensate P-trap, an improperly designed trap for the unit's negative static pressure, a rusted-through pan, or a coil dumping more condensate than the drain can carry. We clear, repair, or re-engineer the condensate path.
A fouled cooling or heating coil, an air-bound hydronic coil, a stuck or backwards valve actuator, or a control-valve that has lost its signal. We verify water flow, coil cleanliness, and actuator stroke to find the heat-transfer fault.
Overcurrent from a binding fan, overvoltage on deceleration, a ground fault in the motor windings, or drive-induced bearing currents. We read the drive fault log, test the motor, and correct the drive parameters or hardware.
Air handling units are the workhorses of commercial HVAC, moving conditioned air through ductwork to every tenant space, while coordinating with chillers, boilers, and the building automation system. A single large AHU can serve an entire floor plate or vertical riser, so when its supply fan, coils, dampers, or VFD fail, the impact is immediate and widespread. Com+ Mechanical services the full range of commercial air handlers, from packaged indoor units in mechanical rooms to large field-erected built-up systems and rooftop AHUs. Our technicians work fluently with belt-driven and direct-drive plenum (plug) fans, chilled-water and DX cooling coils, hot-water and steam heating coils, economizer and mixing-box damper assemblies, VFDs, and the sensors and actuators that tie the unit into your BAS. We diagnose the actual fault, whether it is a mechanical airflow problem, a coil heat-transfer issue, a controls miscommunication, or a drive fault, and restore the unit to design airflow and leaving-air temperature.
From call to comfort in 4 easy steps
We get a technician to the mechanical room, roof, or penthouse, review BAS alarms and trends, and confirm the unit's symptoms with the building engineer on site.
We test the fan, motor, VFD, coils, dampers, and controls to separate a true mechanical or heat-transfer failure from a controls or sensor fault, then explain the finding.
We complete the repair, belt, bearing, actuator, sensor, VFD, coil cleaning, or condensate correction, using commercial-grade parts matched to the unit and its duty.
We measure static pressure, airflow, and leaving-air temperature against design, confirm the unit communicates with the BAS, and document the work for your records.
Factory-assembled air handlers in mechanical rooms or closets, serving a floor, wing, or tenant space, with fan, coil, filter, and damper sections in a single cabinet.
Large custom air handlers assembled on site for high-capacity loads, common in office towers, hospitals, and institutional buildings, with walk-in sections and multiple coils.
Air handlers mounted on the roof or in a penthouse mechanical room, exposed to weather and serving upper floors or full-building distribution through vertical risers.
We service indoor packaged, field-erected built-up, and rooftop air handlers every week, the same systems that condition NYC office, retail, healthcare, and multifamily buildings.
From a thrown fan belt to a freezestat that won't clear to a VFD parameter fault, we handle the airside and the controls side so nothing falls between trades.
No-airflow and freeze-trip events don't keep business hours. We dispatch around the clock across the NYC metro.
Property managers and facility teams running multiple buildings get consistent service, documentation, and a single point of contact across every site we cover.
No fees. No surprises. Just honest service.
The hands-on repair: belts, bearings, actuators, sensors, coil cleaning, condensate correction, or VFD service, with post-repair performance verification.
Scheduled multi-visit maintenance for one unit or a whole portfolio: belts, bearings, coil cleaning, filter changes, and damper checks before they become failures.
Final pricing is scoped after an on-site assessment of the specific unit, its accessibility, and the parts required.
Business+ plans start at $499/year — includes 2 rtu tune-ups, 10% off all services, and priority scheduling.
Factory-trained technicians for all major HVAC manufacturers









Don't see your brand? We service all major manufacturers! Call us to confirm.
Fast, reliable service in your neighborhood
Get answers to common questions about our services
Yes. A no-airflow event, a freezestat trip threatening a hydronic coil, or an overflowing drain pan over occupied space can't wait. We dispatch technicians around the clock across the NYC metro for air handler emergencies.
Yes. We work with property managers and facility teams running multiple buildings throughout the five boroughs, Nassau, Westchester, northern NJ, and Stamford. You get consistent service and documentation across every site, with a single point of contact instead of a different vendor at each building.
Usually yes. Stuffy, under-conditioned spaces often trace to a fouled coil, a slipping belt or under-speed VFD reducing CFM, a stuck economizer damper, or a loaded filter bank. We measure actual airflow and leaving-air temperature against design to find which of those is the cause rather than guessing.
It can. Tuning VFD control, cleaning coils to restore heat transfer, sealing leaking dampers, and correcting economizer operation all cut the energy an air handler wastes, which lowers building emissions counted under Local Law 97. We can flag efficiency opportunities while we're in the unit.
Yes. We service hydronic AHUs with chilled-water and hot-water or steam coils as well as DX units with direct-expansion cooling coils. We also handle the valves, actuators, and controls that tie either type into your chiller plant, boiler plant, or condensing units.
Yes. Our technicians read BAS alarms and trend data as part of diagnosis, verify that sensors and actuators report correctly, and confirm the unit responds to commands after repair. If a points or programming issue sits outside our scope, we'll identify it so your controls vendor can address it.
Manage a building we've serviced? A quick review helps other NYC property managers and building owners find us.
5 stars • 500+ reviews
Our businesses' top picks for heating, cooling & air quality
Equipment services, industry expertise, NYC compliance, and the metro areas we cover.
Whether it's a single AHU dropping airflow on an occupied floor or a fleet of units across your portfolio, Com+ Mechanical diagnoses the real fault and restores supply air to spec, fast. Reach our commercial team to schedule AHU service anywhere in the NYC metro.
Request AHU Service