5.0(65+ reviews)
    24/7 emergency commercial response

    Commercial Boiler Preventive Maintenance for NYC Buildings

    Scheduled boiler care that keeps tenants warm, controls fuel spend, and keeps your building ahead of heating-season failures. Com+ Mechanical builds PM programs around your boiler plant, your occupancy, and your portfolio's uptime requirements across the five boroughs and surrounding metro.

    Boiler Issues a PM Program Catches Early

    Rising fuel bills with no added load

    Soot on the fireside acts as insulation and scale on the waterside blocks heat transfer, both pushing stack temperature up and net efficiency down. A small amount of sooting can cost meaningful efficiency. Combustion tuning and fireside cleaning during PM restore the boiler to its rated burn.

    Boiler short-cycles or locks out on the first cold morning

    Drifting aquastats, a fouled flame sensor, dirty low-water cutoffs, or a sticking gas valve cause nuisance lockouts that surface the moment the plant is asked to run hard. Seasonal startup testing finds and corrects these before tenants are calling about no heat.

    Uneven heat or cold tenant complaints across floors

    Air-bound hydronic loops, failed circulators, stuck zone valves, or a waterlogged expansion tank starve upper floors and far risers. PM purges air, verifies pump and zone operation, and checks tank charge so distribution stays balanced.

    Low-water cutoff fails to prove on test

    A sediment-clogged float chamber or a corroded probe can leave the most important safety device unable to shut the burner on low water, risking a dry-fire. Routine LWCO testing and blowdown keep this life-safety control reliable and code-compliant.

    Visible water or rust at the base of the boiler

    Weeping relief valves, leaking near-boiler fittings, a cracked section, or condensate corrosion show up as staining and puddling. Caught early during inspection, these are planned repairs; ignored, they become a failed boiler in January.

    Yellow or sooting flame and a sulfur or exhaust odor

    A flame burning rich from a worn linkage or restricted air supply produces carbon monoxide and soot, fouling the heat exchanger and creating a combustion-safety hazard. Combustion analysis quantifies CO and resets the burner to a clean, complete burn.

    Why a Boiler PM Program Matters Before Heating Season

    A commercial boiler that sat idle all summer does not come back online clean. Scale builds on the fireside and waterside, low-water cutoffs stick, gas valves drift out of calibration, and combustion shifts rich or lean as linkages wear. The first cold snap in the NYC metro is the worst time to discover any of it, because that is when a no-heat call turns into displaced tenants, emergency-rate repairs, and Department of Buildings exposure. A preventive maintenance program reverses that risk. Com+ Mechanical schedules combustion analysis, safety-control testing, waterside treatment, and a documented seasonal startup so your hot water or steam plant is verified before tenants need it. We service cast-iron sectional, firetube, watertube, and modulating condensing boilers, and we tailor visit frequency to whether you run a single building or a portfolio of them. The result is fewer mid-winter emergencies, tighter fuel efficiency, a longer boiler life, and a paper trail that satisfies your insurer and the city.

    What's Included in Each PM Visit

    Combustion analysis with a calibrated analyzer: O2, CO, CO2, stack temperature, and net efficiency measured, then burner air-fuel ratio and linkage tuned across the firing range
    Low-water cutoff testing and a slow-drain (or probe) verification, plus blowdown of the float chamber to clear sediment on steam and hydronic units
    Operating, limit, and high-limit control testing: aquastats, pressuretrols/vaporstats, modulating controls, and flame-safeguard relay function checked and recorded
    Fireside and waterside inspection: heat-exchanger sections, tubes, baffles, and refractory checked for soot, scale, cracking, and leakage; condensate trap and neutralizer serviced on condensing units
    Gas train and burner service: pilot/igniter, flame sensor or scanner, gas valve seating, manifold pressure, and leak check on the train
    Water treatment and chemistry: sample tested for pH, hardness, and inhibitor level; chemical pot feeder or treatment dosed; expansion tank charge and makeup-water/feed valve verified
    Circulator, pump, and near-boiler piping check: bearings, couplings, packing/seals, air separators, and zone valves inspected; system air purged
    Documented condition report with combustion readings, safety-test results, deficiencies, and recommended corrective work for budgeting

    Benefits of a Com+ Boiler PM Program

    Fewer mid-winter no-heat emergencies — failures are found and fixed on a planned visit instead of during the first cold snap
    Lower fuel spend through combustion tuning and clean heat-transfer surfaces that hold the boiler at peak efficiency
    Longer equipment life — controlled water chemistry and regular service push back the capital cost of boiler replacement
    Verified life-safety controls and a documented inspection trail your insurer and the city can rely on
    Priority response and continuity of service when something does go wrong, because our techs already know your plant
    Predictable maintenance budgeting with planned visits instead of unplanned emergency-rate repairs

    Our Simple Process

    From call to comfort in 4 easy steps

    1

    Plant Assessment

    We survey your boiler room, identify each boiler by type, fuel, and capacity, review controls and near-boiler piping, and note the building's occupancy and heating demands across the property.

    2

    Scoped PM Proposal

    We build a maintenance scope and visit frequency matched to your equipment and uptime needs — including the pre-season startup — and present it as a clear written agreement with task detail.

    3

    Seasonal Startup & Scheduled Visits

    Before heating season we commission the plant with full combustion and safety testing, then return on the agreed schedule to keep controls, chemistry, and burners in spec all winter.

    4

    Reporting & Planned Corrections

    After every visit you receive a condition report with readings and any deficiencies. We schedule corrective work proactively so repairs happen on your timeline, not the boiler's.

    Types of Systems We Install

    Cast-Iron Sectional Boilers

    Common in older NYC multi-tenant and commercial buildings for hot water and steam. Durable but prone to sectional cracking from thermal shock and scale, and sensitive to water chemistry.

    • Section-by-section inspection for cracks and leakage
    • Push-nipple and tie-rod integrity checks
    • Waterside scale control and treatment
    • Combustion tuning across the firing range

    Firetube & Watertube Boilers

    Larger packaged steam and hot-water plants serving sizable commercial buildings and campuses, where tube fouling and refractory condition directly drive efficiency and reliability.

    • Fireside tube and baffle inspection and cleaning
    • Refractory and gasket condition check
    • Low-water-cutoff and operating-control testing
    • Stack-temperature and efficiency analysis

    Modulating Condensing Boilers

    High-efficiency units that extract heat from flue gas, increasingly specified in NYC retrofits. They demand attention to condensate handling, neutralization, and heat-exchanger cleanliness to keep efficiency high.

    • Secondary heat-exchanger inspection and cleaning
    • Condensate trap and neutralizer service
    • Modulating control and flame-signal verification
    • Combustion calibration for low-NOx operation

    Why Property Managers Choose Com+ Mechanical

    Commercial Boiler Specialists

    We work on cast-iron sectional, firetube, watertube, and modulating condensing boilers in commercial and multi-tenant buildings every day — not residential units scaled up. Your plant is our core work.

    Built for the NYC Metro

    We serve the five boroughs plus Nassau, Westchester, northern New Jersey, and Stamford, and we understand the city's heating-season demands and boiler compliance environment that buildings here operate under.

    Portfolio-Ready Service

    Whether you manage one building or many, we standardize PM scope and reporting across your sites so you get consistent service and comparable documentation across the whole portfolio.

    Documentation You Can Use

    Every visit produces combustion readings, safety-test results, and a deficiency log — the records your ownership, insurer, and city filings depend on, organized and on file.

    Transparent Pricing

    No fees. No surprises. Just honest service.

    Boiler Plant Assessment

    Custom Quote

    A one-time inspection and combustion baseline of your boiler room to document condition, test safety controls, and define the right PM scope before you commit to a program.

    • Full boiler-room and equipment survey
    • Combustion analysis and efficiency baseline
    • Safety-control and low-water-cutoff test
    • Written condition report with prioritized recommendations
    Get Free Quote
    Most Popular

    Seasonal PM Program

    Custom Quote

    Our core preventive maintenance program: pre-season startup plus scheduled in-season visits that keep your boiler plant tuned, safe, and efficient through the heating season.

    • Pre-heating-season startup and commissioning
    • Scheduled combustion tuning and safety testing
    • Waterside chemistry and treatment service
    • Circulator, pump, and near-boiler inspection
    • Condition report and deficiency log after every visit
    Get Free Quote

    Portfolio Maintenance Agreement

    Custom Quote

    A multi-building agreement that standardizes boiler PM scope, scheduling, reporting, and priority response across every property you manage, with consolidated documentation.

    • Standardized PM scope across all sites
    • Consolidated reporting and service history
    • Priority response across the portfolio
    • Coordinated seasonal startup scheduling
    • Single point of contact for all buildings
    Get Free Quote

    Final pricing is scoped after a boiler plant assessment, because the work depends on boiler type, count, fuel, and the controls in place.

    Own a Commercial Property?

    Business+ plans start at $499/year — includes 2 rtu tune-ups, 10% off all services, and priority scheduling.

    No ContractsSatisfaction Guarantee
    View Business+ Plans

    Equipment & Brands We Service

    Factory-trained technicians for all major HVAC manufacturers

    Trane logo
    TraneThe Apple of HVACFactory Authorized
    Carrier logo
    CarrierThe OG of Air ConditioningFactory Authorized
    Lennox logo
    LennoxPremium High-EfficiencyFactory Authorized
    American Standard logo
    American StandardTrane's Smarter TwinPreferred Partner
    Rheem logo
    RheemReliable & Drama-FreePreferred Partner
    Bryant logo
    BryantCarrier's Quieter SiblingCertified
    Goodman logo
    GoodmanHonest ValueCertified
    Ruud logo
    RuudRheem's Reliable TwinCertified
    Mitsubishi Electric logo
    Mitsubishi ElectricGold Standard for DuctlessFactory Authorized
    Daikin logo
    DaikinWorld's Largest HVAC ManufacturerFactory Authorized
    Bosch logo
    BoschGerman Engineering ExcellencePreferred Partner
    LG logo
    LGSurprisingly LegitPreferred Partner

    Don't see your brand? We service all major manufacturers! Call us to confirm.

    Proudly Serving Nassau County

    Fast, reliable service in your neighborhood

    Frequently Asked Questions

    Get answers to common questions about our services

    When should we schedule boiler PM before heating season?

    Ideally late summer to early fall, before the first sustained cold. Booking the pre-season startup early gives us time to commission the plant, correct any deficiencies found, and confirm safety controls before tenants need heat — rather than scrambling during the first cold snap. Call (332) 600-4640 to get your building on the schedule.

    Do you offer 24/7 emergency support if a boiler fails between PM visits?

    Yes. PM-program buildings get priority response when something goes wrong off-schedule, and because our technicians already know your plant, controls, and history, we diagnose faster.

    Can you manage boiler maintenance across our whole portfolio?

    Yes. Our Portfolio Maintenance Agreement standardizes PM scope, scheduling, and reporting across every building you manage, with consolidated service history and a single point of contact. You get consistent documentation and comparable records across all sites, whether you run two buildings or twenty.

    How does boiler PM help with efficiency and Local Law 97?

    Local Law 97 ties building emissions to carbon caps, and an inefficiently burning boiler raises both fuel use and emissions. Regular combustion tuning and clean heat-transfer surfaces hold the boiler near its rated efficiency, lowering fuel consumption and the carbon intensity of your heating. PM also produces the combustion and efficiency records that support your building's reporting.

    What documentation do we receive from the program?

    After every visit you get a condition report with combustion readings (O2, CO, stack temperature, net efficiency), safety-control and low-water-cutoff test results, and a logged list of any deficiencies with recommended corrective work. These records support your ownership's budgeting, your insurer's requirements, and city filings.

    Does a PM program cover repairs, or only inspection?

    The program covers the scheduled preventive tasks — combustion tuning, safety testing, water treatment, and inspection. When we find a deficiency, we document it and quote the corrective repair so you can plan it on your budget and timeline. PM-program buildings receive priority scheduling on that repair work.

    Love Our Service? Share Your Experience!

    Manage a building we've serviced? A quick review helps other NYC property managers and building owners find us.

    5 stars • 500+ reviews

    Most Requested Services

    Our businesses' top picks for heating, cooling & air quality

    heating

    Commercial Boiler Repair

    Learn More
    heating

    Commercial Boiler Installation

    Learn More
    additional

    Commercial Boiler Replacement Cost Factors

    Learn More
    additional

    Commercial Boiler Guide

    Learn More
    heating

    Commercial Water Heater Installation

    Learn More

    Lock In Your Boiler Plant Before the Cold

    A preventive maintenance program turns boiler care from a winter emergency into a planned, budgeted routine — fewer no-heat calls, tighter fuel spend, longer equipment life, and documentation your ownership and the city can rely on. Get your building scoped and on the schedule before heating season arrives. Call Com+ Mechanical at (332) 600-4640 or request a maintenance proposal today.

    Get a Maintenance Proposal